CB-7080 & CB-7080D Counter/Timer User's Guide $AA6N
2-24
$AA6N
Description: Reset counter 0 or counter 1 to the preset value and clear the overflow flag. Refer to "Preset
value setting" for more information.
Syntax: $AA6N[chk](cr)
$ A delimiter character
AA 2-character HEX module address, from 00 to FF
N=0 Counter 0
N=1 Counter 1
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Response:
Valid response !AA[chk](cr)
Invalid response ?AA[chk](cr)
no response Syntax error, communication error or address error
! A delimiter character indicating a valid response
? A delimiter character indicating an invalid response
AA 2-character HEX module address
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr)=0x0D
Examples:
Reads preset value of Counter 0.
command: @01G0(cr)
response: !0100000000(cr)
Preset value=0xABCD:
command: $0160(cr)
response: !01(cr)
Reset counter 1 to preset value 0xABCD:
command @01G1(cr)
response 010000ABCD(cr)
command: $0161(cr)
response: !01(cr)