
Section 3 Command Descriptions
3.19
Inhibit Qn
The
Inhibit
control command allows software control of the
Inhibit
line,
independent of any other I/O activities. The 'set' and 'clear' levels of the
Inhibit
line are
determined by the
Invert
command.
Q0
Clear the
Inhibit
line (return to unasserted state)
Q1
Set the
Inhibit
line (place in the asserted state)
Example:
CLEAR 718
reset the
Digital488
OUTPUT 718;"Q1X"
set the Inhibit line
Kommentare zu diesen Handbüchern