Section 1 Introduction
2.18
4096 memory locations are available in its internal buffers. If
available memory drops below 4096 bytes, the Serial488/4 un-
asserts (low) the
RTS+
signal. With
RTS/CTS
handshaking
selected, the
RTS+
signal may also asserted and un-asserted under
program control by using the (
N2
) and (
N1
) handshake control
commands respectively.
If
XON/XOFF
handshaking (
G1
) is selected, the
RTS+
line
may either be programmed as either permanently asserted (high)
or to output sixteen times the baud rate clock. These options are
selected using the handshake control command (
Nn
).
If No handshaking (
G2
) is selected, the
RTS+
line may either be
programmed as either permanently asserted (high), permanently
un-asserted (low), or to output a signal sixteen times the baud rate
clock. These options are selected using the handshake control
command (
Nn
).
RTS Request To Send (output) / 16 x Baud Clock (output)
The
RTS-
output is used as a hardw are handshake line w ith RS-
422 devices The pin functions identically to
RTS+
except that its
polarity is inverted. This signal is low true.
GND Ground
This signal sets the ground reference point for the other RS-232
input and output signals.