PCI-DAS6071 User's Guide Specifications
41
Analog trigger
Table 16. Analog trigger specifications
Analog trigger sources
Software selectable
External: ATRIG input
CH0 IN through CH63 IN, first channel in scan
CH0 IN through CH63 IN: ± Full-scale, range dependent
External analog: Software-configurable for:
Positive or Negative slope
External analog: Software-configurable for:
Above or below reference
Positive or negative hysteresis
In or out of window
CH0 IN through CH63 IN: 2.0 MHz
Analog I/O calibration
Table 17. Analog I/O calibration specifications
Auto-calibration, calibration factors for each range stored on board in non-
volatile RAM.
Onboard calibration reference
DC Level: 5.000 V± 2.5 mv. Actual measured values stored in EEPROM.
Tempco: 5ppm/°C max, 2 ppm/°C typ
Long-term stability: 20 ppm,
T = 1000 hrs, non-cumulative
Digital I/O
Table 18. Digital I/O specifications
Discrete, 5V/TTL compatible
8 bits, independently programmable for input or output. All pins pulled up to
+5 V via 47 K resistors (default). Positions available for pull-down to ground.
Hardware selectable via solder gap.
2.0 V min, 7.0 V absolute max
0.8 V max, –0.5 V absolute min
Output high voltage
(IOH = –32 mA)
Output low voltage
(IOL = 32 mA)
Input mode (high impedance)