Section 5 Command Descriptions
5.37
HELLO
The
HELLO
command is used to verify communication with the Micro488/EX,
and to read the software revision number. When the command is sent, the
Micro488/EX returns a string similar to the following:
Micro488/EX Revision N.N Copyright (C) 1988 IOtech Inc.
where
N.N
is the revision and release number of the firmware.
SYNTAX HELLO
or
HE
RESPONSE Micro488/EX Revision N.N Copyright (C) 1988 IOtech Inc.
N.N is the revision and release number of the firmware.
MODE Any
BUS STATES None
EXAMPLE
PRINT#1,"HELLO"
Get the
HELLO
response
INPUT#1,A$
PRINT A$
and display it.