Single WaveBook Systems, 4 Examples
Example 1: WaveBook/516E System with two WBK10A Modules
Device Interface Side Channel Input Side
WaveBook/516E System
with 2 WBK10A Modules
WBK10A (2
n
d
)
WBK10A (1
st
)
WaveBook/516E
Power
Ethernet
Power
Lines and Cables Used in Example 1, excluding channel input connections.
1. Power Supply - To the WaveBook/516E POWER IN DIN 5 connector, +10 VDC to +30 VDC,
typically from a TR-40U power adapter.
2. Power Supply - To the first WBK10A’s POWER IN DIN 5 connector, +10 VDC to +30 VDC,
typically from a TR-40U power adapter.
3. Power Supply – From the first WBK10A’s POWER OUT DIN 5 connector, +10 VDC to +30 VDC,
to the second WBK10A’s POWER IN DIN 5 connector via a CA-115 Power Cable.
4. Ethernet – From the WaveBook/516E ETHERNET jack to a 10/100BaseT Ethernet Network or to
the ETHERNET jack on a PC. Applicable Ethernet patch cables (1.5-foot or 7-foot) are CA-242 and
CA-242-7, respectively.
5. Expansion Control – From WaveBook/516E EXPANSION CONTROL to the first WBK10A’s
EXPANSION CONTROL IN. Connection is via a 15-pin CA-129 cable.
6. Expansion Control – From the first WBK10A’s EXPANSION CONTROL OUT to the second
WBK10A’s EXPANSION CONTROL IN. Connection is via a 15-pin CA-129 cable.
7. Expansion Signal – From the second WBK10A’s EXPANSION SIGNAL OUT to the first
WBK10A’s EXPANSION SIGNAL IN. Connection is via a BNC coaxial CA-150 cable.
8. Expansion Signal – From the first WBK10A’s EXPANSION SIGNAL OUT to the
WaveBook/516E’s EXPANSION SIGNAL IN. Connection is via a BNC coaxial CA-150 cable.