Measurement-computing Personal Daq rev.6.0 Bedienungsanleitung Seite 88

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 170
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 87
10 Update Digital Outputs Updates the digital output channels. This item is only enabled when the digital
output channels are not updated and the acquisition state is idle.
11 Save Power-up Settings Saves the current power-up settings for all devices in the configuration. The
power-up settings take effect when the device is first plugged into an active USB
port.
12 Chart Display Opens the Chart Display, where data is displayed in graphical in a chart format. If
Chart Display is already open, selecting this item gives the window focus.
13 Bar Graph Meters Display Opens the Bar Graph Meters, where data is displayed in a bar graph format. If Bar
Graph Meters is already open, selecting this item gives the window focus.
14 Analog Meters Display Opens the Analog Meters Display, where data is displayed in an analog meter
format. If Analog Meters Display is already open, selecting this item gives the
window focus.
15 Digital Meters Display Opens the Digital Meters Display, where data is displayed in a digital meter format.
If Digital Meters is already open, selecting this item gives the window focus.
16 Use Data Destination Turns the Use Data Destination feature on or off.
17 Set Data Destination Cell Sets the data destination cell to the “active” cell in the current workbook.
18 Use Data Header Turns the Use Data Header feature on or off.
19 Options… Opens Personal DaqViewXL’s Options Dialog.
20 Preferences… Opens Personal DaqViewXL’s Preferences Dialog. From this dialog box you can
use the General and Measurement Units dialog boxes as described below.
General Allows you to select “untitled” or “pDaq”
configurations for the default filename used by
Personal Daq. Note that Personal DaqView automatically
loads the last saved configuration file. The lower portion of
the General screen pertains to configuration file settings.
Measurement Units Allows you to set the desired default
units for the Channel Configuration Window’s spreadsheet.
Note that scale and offset automatically reset to a pre-
designated default according to the unit selected.
Changing the measurement unit defaults does not
immediately affect the Channel Configuration Window’s
spreadsheet columns. For example: If you set your voltage
default to µV, but the channels are set with V units, they will
retain the V units. However, changing these channels to
temperature, then back to voltage would result in the default
units (µV) and the associated scale & offset. The new
default units are also applied to all channels when a new
configuration file is created.
Preferences Screen Captures (Condensed Images)
21 About… Provides version information for the active Personal DaqViewXL add-in and the
Personal DaqView application.
22 Help… Launches the Personal DaqViewXL section of the Personal DaqView help file.
6 491-0905, rev 3.0 918596 Personal DaqViewXL User’s Guide
Seitenansicht 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 169 170

Kommentare zu diesen Handbüchern

Keine Kommentare