CB-7013, CB-7033 Users Manual
2.7 $AA2
Description: Read Configuration
Syntax: $AA2[CHK](cr)
$ Delimiter character
AA Address of reading module (00 to FF)
2 Command for read configuration
Response: Valid Command:
!AATTCCFF[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
! Delimiter for valid command.
? Delimiter for invalid command.
AA Address of response module (00 to FF).
TT Type code of module (reference Sec. 1.9).
CC Baud rate code of module (reference Sec. 1.9).
FF Data format of module (reference Sec. 1.9).
Example:
Command: $012 Receive: !01200600
Read address 01 configuration, return successful
Command: $022 Receive: !02230602
Read address 02 configuration, return successful.
Related Command:
Sec2.1 %AANNTTCCFF
Related Topics:
Sec. 1.9 Configuration Tables, Sec3.1 INIT* pin Operation.