53
CB-7011/CB-7011D, CB-7018 User’s Manual
2.31 @AACE
Description: Clear Event Counter
Note: The command is for CB-7011/11D/11P/11PD only.
Syntax: @AACE[CHK](cr)
@ delimiter character
AA address of setting module (00 to FF)
CE command for clear event counter
Response: Valid Command: !AA[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
! delimiter for valid command
? delimiter for invalid command
AA address of response module(00 to FF)
Example:
Command: @01RE Receive: !0101234
Read address 01 event counter, return 1234.
Command: @01CE Receive: !01
Clear address 01 event counter, return success.
Command: @01RE Receive: !0100000
Read address 01 event counter, return 0.
Related Command:
Sec. 2.30 @AARE
Related Topic:
Sec. 3.4 Digital Input and Event Counter