PidPRO & PidPRO+ 919092 5-17
Database Item View Window
Each record in a PID Database has several fields, which can be viewed in the Database Item View window. To
access the window either:
(a) click the Edit Database Record tool (see page 5-12), or
(b) double-click the desired PID record in the Network Identifier Database list (see page 5-7).
For each record, two views are accessible from the tabs at the top of the window; these are: Detailed View and
Summary View. Since these are two different ways of viewing the same information, changing field values in one
view will change related field valus in the other view.
Detailed View Summary View
The fields in the Summary View are identical to those in the DBK70Config program (PidPRO’s predecessor). This
view is primarily for users migrating from that software. However, the Detailed View provides an easier interface
to the fields and provides several automatic calculation features so that offsets and scales do not need to be
developed manually.
* No field associated means that there is no one directly associated field between Detailed View and Summary View
for a given parameter.
Database Item View Window – Field Labels*
Detailed View Summary View Detailed View Summary View
1 Name Name 14 Raw
No field associated*
2 Comments Comments 15 Low Limit / High Limit
No field associated*
3 Source Channel Source Channel 16 Units/Bit
No field associated*
4 Message Send Rate Update Rate 17 Binary Point
No field associated*
5 Msg 1 and Msg 2 Message 18 Range Low /
Range High
No field associated*
6 If no match in __mS Timeout
7 set chan to µV Default Value
19 Analog To Engineering
Units Conversion
Analog To Engineering
Units Conversion
8 Filter Filter 20
No field associated*
Output Scale
9 Mask Filter 21
No field associated*
Output Offset
10 Start Bit Index 22
No field associated*
Display Scale
11 Data Length (bits) Length 23
No field associated*
Display Offset
12 Format Storage Type
13 Byte Order Option Value