Chapter 2 Digital I/O Library
ADAC LabVIEW VI
1
45
Were period(usec) is the debounce time required.
For detailed definitions see the 5600 manuals ADVANCED
PROGRAMMING
TECHNIQUES.
error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.
Device Handle out Device Handle out contains the value of Device Handle in.
error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.
ADAC Get 5600 Port Struct
This VI gets the digital I/O port settings for the 5600 Series cards. Refer to the 5600
manual for detailed information on each setting. This VI is only used with the 5600
Series.
Device Handle (0) Device Handle is a numeric value that is used to identify the device
subsystem. The default Device Handle is 0.
error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.
Device Handle out Device Handle out contains the value of Device Handle in.
5600 PORT STRUCT
Port Resolution Port Resolution is a numeric value that represents the desired
number of DIO port bits, either 8 or 16. The DIO ports DIN0 can be either 8 or
16 bit ports and DIN1can only be an 8 bit port. When DIN0 is set for 16 bit
Seitenansicht 150