© 1998, 1999, 2000 by IOtech, Inc. November 2001 Printed in the United States of America
DataShuttle and DynaRes
User’s Manual
for Data Acquisition and Control
the smart approach to instrumentation
IOtech, Inc.
25971 Cannon Road
Cleveland, OH 44146-1833
Phone: (440) 439-4091
Fax: (440) 439-4093
E-mail (sales): [email protected]
E-mail (post-sales): productsupport@iotech.com
Internet: www.iotech.com
DataShuttle and DynaRes
Users Manual
for Data Acquisition and Control
p/n
1051-0901
Rev.
2.0
Seitenansicht 0
1 2 3 4 5 6 ... 125 126

Inhaltsverzeichnis

Seite 1 - DataShuttle and DynaRes

© 1998, 1999, 2000 by IOtech, Inc. November 2001 Printed in the United States of AmericaDataShuttle and DynaRes User’s Manualfor Data Acquisition and

Seite 2

1-2 Introduction & Installation of the Data Shuttle 11-13-01DataShuttle and DynaResThe DataShuttle together with our software – such as DASYLab

Seite 3

12-4 Applications Primer11-12-01DataShuttle and DynaRes

Seite 4

DataShuttle and DynaRes11-12-01Analog Input & Output 13-1Analog Input & Output 13Analog Input & OutputThermocouplesThermocouples are the

Seite 5 - Table of Contents

13-2 Analog Input & Output11-12-01DataShuttle and DynaResFigure 13-1. Thermocouple ConnectionsWhen a resistor is installed at R5 and the therm

Seite 6 - 5 - DynaRes - Technical Notes

DataShuttle and DynaRes11-12-01Analog Input & Output 13-3Select the proper thermocouple for the temperature range and accuracy required using th

Seite 7 - 10 - QuickLog Introduction

13-4 Analog Input & Output11-12-01DataShuttle and DynaResStrain GagesStrain gages are made of a wire or resistor that changes resistance when st

Seite 8

DataShuttle and DynaRes11-12-01Analog Input & Output 13-5Figure 13-2. Strain Gage ConnectionsPiezoelectric SensorsOur data acquisition boards

Seite 9 - Introduction

13-6 Analog Input & Output11-12-01DataShuttle and DynaResFigure 13-3c shows an amplified piezoelectric sensor configuration. Many piezoelectric

Seite 10 - Dynamic Resolution

DataShuttle and DynaRes11-12-01Analog Input & Output 13-7The capacitor C and the resistor R3 form a high-pass filter network, which specifies th

Seite 11 - Features and Configurations

13-8 Analog Input & Output11-12-01DataShuttle and DynaResRTD Ranges & ResolutionCurrent SetResistorRTD TemperatureRange16-Bit Resolution(Ohm

Seite 12 - DataShuttle Model Variations

DataShuttle and DynaRes11-12-01Analog Input & Output 13-9RTD AccuracyCurrent SetResistorRTD 16-Bit Accuracy(Ohms) (Ohms) (Degrees C)10K 50 0.820

Seite 13 - DataShuttle-RTD

DataShuttle and DynaRes11-13-01Introduction & Installation of the DataShuttle 1-3Features and ConfigurationsAnalog Input Channels DataShuttle-16

Seite 14 - DataShuttle-5B

13-10 Analog Input & Output11-12-01DataShuttle and DynaResFigure 13-5. Connections for RTDsCurrentFigure 13-6 shows the connections for curren

Seite 15 - Installing Your DataShuttle

DataShuttle and DynaRes11-12-01Analog Input & Output 13-11Figure 13-6. Current ConnectionsHigh Voltage DividerOur data acquisition boards and

Seite 16 - Physical Installation

13-12 Analog Input & Output11-12-01DataShuttle and DynaResFigure 13-8b shows a connection that may by used where the load is already connected t

Seite 17 - Next Steps

DataShuttle and DynaRes11-12-01Analog Input & Output 13-13For currents other than 4-20mA, use the connection of Figure 13-9d. The channel must

Seite 18

13-14 Analog Input & Output11-12-01DataShuttle and DynaRes

Seite 19 - Block Diagram

DataShuttle and DynaRes11-12-01Digital I/O 14-1Digital I/O 14Digital Input & OutputThis chapter provides instruction for digital I/O application

Seite 20

14-2 Digital I/O11-12-01DataShuttle and DynaResFigure 14-1. High Power Output ConnectionsIf the load is a DC load, such as motor, pump, or valve,

Seite 21 - Auxiliary Components

DataShuttle and DynaRes11-12-01Digital I/O 14-3Figure 14-2. High Power DC Input ConnectionsDC inputs should be connected with the correct polarity

Seite 22 - Power Supplies

14-4 Digital I/O11-12-01DataShuttle and DynaResFigures 14-2c and 14-3c show switches connected as in Figure 14-2a and 14-3a, except that they share

Seite 23 - Examples

DataShuttle and DynaRes11-12-01Digital I/O 14-5Frequency/Rate MeasurementFlow meters and tachometers put out pulses that are usually measured as a r

Seite 24 - Example 3: Ground loops

1-4 Introduction & Installation of the Data Shuttle 11-13-01DataShuttle and DynaResFor More InformationFor more information about the capabiliti

Seite 25 - &$87,21

14-6 Digital I/O11-12-01DataShuttle and DynaResIf the gate interval is one second and pulses come in at the rate of 100 per second (100 Hertz freque

Seite 26 - Installing Pull-up Resistors

DataShuttle and DynaRes 11-13-01 Appendix A-1Appendix A--Thermocouple Application Tips AWhen implementing thermocouple applications, the following poi

Seite 27 - Counter/Timer

Appendix A-2 11-13-01 DataShuttle and DynaRes• You can calibrate to your own temperature measurement by adjusting CCAL in the Calib.Dat file. Add75 po

Seite 28 - If You Need Customer Support

DataShuttle and DynaRes11-12-01Glossary - 1GlossaryData Acquisition GlossaryAccuracyIn data acquisition applications, accuracy refers to how close rep

Seite 29 - Troubleshooting: Operation

Glossary - 211-12-01DataShuttle and DynaResDigitalA quantity that has discrete levels. The number of people in a room is a digital quantity. See “Anal

Seite 30

DataShuttle and DynaRes11-12-01Glossary - 3ResolutionThe smallest increment that can be detected in a quantity. Resolution is often specified in bits

Seite 31 - Product Specifications

Glossary - 411-12-01DataShuttle and DynaRes

Seite 32 - DataShuttle-16 RTD Accuracy

DataShuttle and DynaRes11-13-01Introduction & Installation of the DataShuttle 1-5DataShuttle-RTDThe DataShuttle RTD models are specifically desi

Seite 33

1-6 Introduction & Installation of the Data Shuttle 11-13-01DataShuttle and DynaResDataShuttle-TCThe DS-16-8-TC is the best model for thermocoup

Seite 34 - Analog Output

DataShuttle and DynaRes11-13-01Introduction & Installation of the DataShuttle 1-7Before installing 5B or opto22 isolation modules, it will be ne

Seite 35 - General Information

1-8 Introduction & Installation of the Data Shuttle 11-13-01DataShuttle and DynaResIn any event, please refer to the software provider’s install

Seite 36

DataShuttle and DynaRes11-13-01Introduction & Installation of the DataShuttle 1-9A Note on Board Numbers– When you are using multiple units in y

Seite 37 - Introduction to the DynaRes 3

1-10 Introduction & Installation of the Data Shuttle 11-13-01DataShuttle and DynaRes

Seite 38

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-1DataShuttle - Technical Notes 2Although the technical notes presented in the fo

Seite 40 - DynaRes System Requirements

2-2 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResEDITCALDataShuttles are calibrated at the factory prior to shipment, and should n

Seite 41 - Installing the DynaRes 4

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-3Auxiliary ComponentsStarting EDITCALAuxiliary Components are required by some s

Seite 42 - Physical Board Installation

2-4 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResPower SuppliesA Note on Power Supplies – The DataShuttle supplies the following v

Seite 43

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-5ExamplesExample 1: Current Sense ResistorThe DataShuttle can measure currents u

Seite 44 - Measuring Current

2-6 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResExample 3: Ground loopsOccasionally there is an installation where the ground con

Seite 45 - Setting the Base Address

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-7Current OutputsMost current outputs connect to current loop devices, such as co

Seite 46 - Changing Hardware Interrupts

2-8 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResDigital ComponentsInstalling Digital ModulesSchematic for Digital Auxiliary Compo

Seite 47 - DynaRes - Technical Notes 5

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-9Installing Current Limiting ResistorsTo limit the current in the digital input

Seite 48

2-10 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaRes4. Disconnect additional DataShuttles and printers in your setup.5. Connect the

Seite 49 - EDITCAL Utility

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-11Troubleshooting: OperationHintsIt’s essential to have exactly one ground refe

Seite 50

Warranty InformationYour IOtech warranty is as stated on the product warranty card. You may contact IOtech by phone,fax machine, or e-mail in regard

Seite 51

2-12 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResBefore Calling Customer SupportCheck the following key areas to validate whether

Seite 52

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-13Product SpecificationsAccuracy DataShuttle-16 Accuracy & Resolution-RangeT

Seite 53 - DynaRes 8/16 RTD Accuracy

2-14 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResThermocouple Conditions – Same as General Conditions. Does not include the accur

Seite 54 - Input Protection

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-15RTD Conditions – Same as General Conditions. Does not include the accuracy of

Seite 55 - General Conditions

2-16 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaResAnalog InputScan Rate – Scan rate is the rate in Hertz (or, samples per second)

Seite 56

DataShuttle and DynaRes 11-13-01 DataShuttle - Technical Notes 2-17General InformationGeneral Specifications of the DataShuttle• Analog input ope

Seite 57

2-18 DataShuttle - Technical Notes 11-13-01DataShuttle and DynaRes

Seite 58 - Types of Terminal Panels

DataShuttle and DynaRes11-09-01 Introduction to the DynaRes 3-1Introduction to the DynaRes 3Thank you for selecting the DynaRes board for your pro

Seite 59 - T71 Terminal Panel

3-2 Introduction to the DynaRes11-09-01DataShuttle and DynaResYou can measure temperature, for example, by selecting from among 11 different thermoc

Seite 60 - Reference Tables

DataShuttle and DynaRes11-09-01 Introduction to the DynaRes 3-3Features and ConfigurationsThe DynaRes line consists of two models: the DynaRes 8 a

Seite 62

3-4 Introduction to the DynaRes11-09-01DataShuttle and DynaResConsult our Applications manual to learn more about data acquisition, process control

Seite 63

DataShuttle and DynaRes11-09-01Installing the DynaRes 4-1Installing the DynaRes 4OverviewGetting your DynaRes data acquisition and process control b

Seite 64 - Digital Auxiliary Components

4-2 Installing the DynaRes11-09-01DataShuttle and DynaResPreviously in UseIf, on the other hand, your board has been in use previously in another co

Seite 65 - Troubleshooting Q & A

DataShuttle and DynaRes11-09-01Installing the DynaRes 4-3Physical InstallationTo Install the DynaRes Board1. TURN THE COMPUTER OFF. Never remove the

Seite 66

4-4 Installing the DynaRes11-09-01DataShuttle and DynaResMeasuring CurrentIf you are going to connect a current, rather than a voltage, to one or mo

Seite 67

DataShuttle and DynaRes11-09-01Installing the DynaRes 4-5Determine which is to be the First Board. (This is easy, if it is the sole board.) Then tur

Seite 68

4-6 Installing the DynaRes11-09-01DataShuttle and DynaResBase Address SettingsPossible DynaRes Base Address SettingsValue Switch Positions*1 2

Seite 69

DataShuttle and DynaRes11-13-01DynaRes - Technical Notes 5-1DynaRes - Technical Notes 5OverviewAlthough operations in this chapter are seldom necess

Seite 70

5-2 DynaRes - Technical Notes11-13-01DataShuttle and DynaResPinouts of Channels 9-16 on the DynaRes 16(at Back Panel Connector)Block DiagramBlock Di

Seite 71 - Installing the ACAO 8

DataShuttle and DynaRes11-13-01DynaRes - Technical Notes 5-3RecalibrationYour DynaRes uses an exclusive calibration technology to achieve great stab

Seite 72

Table of Contents1 - Introduction & Installation of theDataShuttleIntroduction …… 1-1General Information …… 1-1Development System …… 1-1Expandabil

Seite 73 - Setting the Switches

5-4 DynaRes - Technical Notes11-13-01DataShuttle and DynaResTroubleshooting: InstallationIf you experience difficulty in getting your data acquisit

Seite 74 - Multiple Boards

DataShuttle and DynaRes11-13-01DynaRes - Technical Notes 5-5Troubleshooting: OperationHintsDuring operation, it’s good practice to short all analog

Seite 75 - Setting the Switch

5-6 DynaRes - Technical Notes11-13-01DataShuttle and DynaResProduct Specifications: DynaRes 8/16Specifications of the DynaRes 8 and DynaRes 16Accura

Seite 76

DataShuttle and DynaRes11-13-01DynaRes - Technical Notes 5-7DynaRes 8/16 Thermocouple AccuracyType Range (°C.) Resolution (°C.) Accuracy (°C.)J -210

Seite 77 - Base Address Settings

5-8 DynaRes - Technical Notes11-13-01DataShuttle and DynaResRTD Conditions – Same as General Conditions. It does not include the accuracy of the RT

Seite 78 - 8-8 Installing the ACAO

DataShuttle and DynaRes11-13-01DynaRes - Technical Notes 5-9Resolution/Scan RateSelectable in software:DynaRes 8/16 Resolution And Scan Rate*Resolut

Seite 79 - Overview

5-10 DynaRes - Technical Notes11-13-01DataShuttle and DynaResOperating Temperature Ambient – 0 to 50 degrees Celsius.Physical Dimensions– 6.7"

Seite 80

DataShuttle and DynaRes11-12-01Introduction to Terminal Panels 6-1Introduction to Terminal Panels 6For most data acquisition applications using a pl

Seite 81 - Editing Calibration Files

6-2 Introduction to Terminal Panels11-13-01DataShuttle and DynaResTo Install a Terminal Panel1. Verify that the panel is compatible with the instal

Seite 82 - Calibration File Format

DataShuttle and DynaRes11-12-01Introduction to Terminal Panels 6-3T71 Terminal PanelDesigned for use with the DynaRes data acquisition boards, the T

Seite 83 - Using EDITCAL

4 - Installing the DynaResOverview …… 4-1Verifying DynaRes Switch Settings …… 4-1Single Board …… 4-1Multiple Boards …… 4-1Previously in Use …… 4-2Phys

Seite 84 - EDITCAL Selections

6-4 Introduction to Terminal Panels11-09--01DataShuttle and DynaResReference TablesEach of the terminal panels differs from the others in some way,

Seite 85

DataShuttle and DynaRes11-12-01Introduction to Terminal Panels 6-5When two T71s are used with a 16-channel DynaRes, both terminal panels have access

Seite 86 - 0 to 10V 0.02% 0.01%

6-6 Introduction to Terminal Panels11-09--01DataShuttle and DynaResAnalog Auxiliary Component Area on Terminal PanelExamplesExample 1: Current sense

Seite 87 - Auxiliary Power Output

DataShuttle and DynaRes11-12-01Introduction to Terminal Panels 6-7Example 2: 3-Wire RTD componentsThe most popular connection for RTDs is the three

Seite 88

6-8 Introduction to Terminal Panels11-09--01DataShuttle and DynaResTo install this resistor the wire at R5 must first be removed. After R5 has been

Seite 89 - QuickLog Introduction 10

DataShuttle and DynaRes11-12-01Introduction to Terminal Panels 6-9The terminals for that I/O have now changed their function from low voltage I/O to

Seite 90 - Setting Up QuickLog

6-10 Introduction to Terminal Panels11-09--01DataShuttle and DynaResProduct SpecificationsAccuracyCold Junction Compensation ErrorType 25°C 15° &

Seite 91 - Specifications

DataShuttle and DynaRes11-12-01Introduction to Terminal Panels 6-11On T71 Terminal Panels Only• Outputs are high voltage open collector with pull-up

Seite 92 - Chart Configuration

6-12 Introduction to Terminal Panels11-09--01DataShuttle and DynaRes

Seite 93 - Edit Menu

DataShuttle and DynaRes11-12-01Introduction to the ACAO Board 7-1Introduction to the ACAO Board 7Thank you for selecting the ACAO for your project.O

Seite 94 - Options Menu: General

8 - Installing the ACAOOverview …… 8-1Verifying ACAO Switch Settings …… 8-1Single Board …… 8-1Multiple Boards …… 8-1Previously In Use …… 8-2Physical B

Seite 95 - Options Menu: Chart

7-2 Introduction to the ACAO Board11-12-01DataShuttle and DynaResFeatures and ConfigurationsAnalog Output ChannelsThe ACAO-12-2 has two output chann

Seite 96 - Help Menu

DataShuttle and DynaRes11-12-01Installing the ACAO 8-1Installing the ACAO 8OverviewGetting your ACAO data acquisition and process control board up a

Seite 97 - Applications Primer 12

8-2 Installing the ACAO11-12-01DataShuttle and DynaResIllustration of ACAO Data Acquisition Board, Showing Physical InstallationPreviously In UseIf,

Seite 98 - Digital Connections

DataShuttle and DynaRes11-12-01Installing the ACAO 8-3Physical InstallationTo Install the ACAO Board1. TURN THE COMPUTER OFF! Never remove the cove

Seite 99 - Applications Primer 12-3

8-4 Installing the ACAO11-12-01DataShuttle and DynaRes(For ACAO-12-8 boards, Channels Three and Four are paired similarly, as are Channels Five and

Seite 100 - 12-4 Applications Primer

DataShuttle and DynaRes11-12-01Installing the ACAO 8-5This number determines, among other things, the sequence in which the software reads multiple

Seite 101 - Analog Input & Output 13

8-6 Installing the ACAO11-12-01DataShuttle and DynaResACAO Board Number Switch SettingsBoardNumberSwitch Positions*5 6 7 80 (disabled) D D

Seite 102

DataShuttle and DynaRes11-12-01Installing the ACAO 8-72. Change the Setting 300H is the normal base address. It consists of all four DIP switches

Seite 103 - Thermocouple Types

8-8 Installing the ACAO11-12-01DataShuttle and DynaRes

Seite 104 - Strain Gages

DataShuttle and DynaRes11-13-01ACAO Analog Output & Control Board Technical Notes 9-1ACAO Analog Output & Control Board Technical Notes 9 Ov

Seite 105 - Piezoelectric Sensors

12 - Applications PrimerApplications Reference …… 12-1Connection Types …… 12-1Analog Input & Output Applications …… 12-1Digital I/O Applications …

Seite 106

9-2 ACAO Analog Output & Control Board Technical Notes11-13-01DataShuttle and DynaResBlock Diagram of the ACAO (All Models)RecalibrationYour ACA

Seite 107

DataShuttle and DynaRes11-13-01ACAO Analog Output & Control Board Technical Notes 9-3Editing Calibration FilesDepending on your usage of the ACA

Seite 108 - RTD Ranges & Resolution

9-4 ACAO Analog Output & Control Board Technical Notes11-13-01DataShuttle and DynaResMultiple Boards/PanelsChanging the Quantity of Boards – A s

Seite 109 - RTD Accuracy

DataShuttle and DynaRes11-13-01ACAO Analog Output & Control Board Technical Notes 9-5CALOUT.DAT NotesThe third line in the file has the serial n

Seite 110

9-6 ACAO Analog Output & Control Board Technical Notes11-13-01DataShuttle and DynaResEDITCAL SelectionsTo Select a FunctionOnce EDITCAL is up an

Seite 111 - Voltage Output

DataShuttle and DynaRes11-13-01ACAO Analog Output & Control Board Technical Notes 9-7Troubleshooting: OperationOperating Qs And As1. Problem:

Seite 112 - Current Output

9-8 ACAO Analog Output & Control Board Technical Notes11-13-01DataShuttle and DynaResProduct SpecificationsAnalog OutputsThe ACAO-12-2 features

Seite 113

DataShuttle and DynaRes11-13-01ACAO Analog Output & Control Board Technical Notes 9-9In Current Output Mode• Temperature Drift:With self-calibra

Seite 114

9-10 ACAO Analog Output & Control Board Technical Notes11-13-01DataShuttle and DynaRes

Seite 115 - Digital I/O 14

DataShuttle and DynaRes11-12-01QuickLog Introduction 10-1QuickLog Introduction 10General InformationOur primary objective is to provide you with dat

Seite 116 - 14-2 Digital I/O

DataShuttle and DynaRes11-13-01Introduction & Installation of the DataShuttle 1-1Introduction & Installation of the DataShuttle 1Introductio

Seite 117 - Digital I/O 14-3

10-2 QuickLog Introduction11-12-01DataShuttle and DynaResSetting Up QuickLogMake sure that your QuickLog package is complete. In addition to this pr

Seite 118 - Cascaded Counter/Timers

DataShuttle and DynaRes11-12-01QuickLog Introduction 10-3SpecificationsMeter Display ScreensTypes of I/O Supported – Analog In, Analog Out, Digital

Seite 119 - Frequency/Rate Measurement

10-4 QuickLog Introduction11-12-01DataShuttle and DynaResI/O Configuration By ChannelThe input and/or output of each channel can be configured using

Seite 120 - 14-6 Digital I/O

DataShuttle and DynaRes 11-13-01 Getting Started with QuickLog 11-1Getting Started with QuickLog 11General InformationQuickLog is entirely menu-driv

Seite 121 - Appendix A

11-2 Getting Started with QuickLog 11-13-01 DataShuttle and DynaResOptions Menu: GeneralSample And Log RateYou may select the Sample Rate, in Hz, wh

Seite 122

DataShuttle and DynaRes 11-13-01 Getting Started with QuickLog 11-3Options Menu: InputsThis window allows you to define which readings will be displ

Seite 123 - Glossary

11-4 Getting Started with QuickLog 11-13-01 DataShuttle and DynaResChart MenuUnlike the Options menu, these selections do not cause the Chart data t

Seite 124 - Glossary - 2

DataShuttle and DynaRes11-12-01Applications Primer 12-1Applications Primer 12Our primary objective is to provide you with data acquisition systems t

Seite 125 - Glossary - 3

12-2 Applications Primer11-12-01DataShuttle and DynaResSensor ConnectionsThere are several general topics regarding sensor connections that must fir

Seite 126 - Glossary - 4

DataShuttle and DynaRes11-12-01Applications Primer 12-3Special Note For Thermocouple ApplicationsIn addition to the thermocouple application instruc

Verwandte Modelle: DynaRes

Kommentare zu diesen Handbüchern

Keine Kommentare